Minimally Invasive Plate Osteosynthesis for Distal Radius Fractures: Are There Any Advantages Against Conventional Technique?

封面

如何引用文章

详细

Purpose of the study — to illustrate the potential and to evaluate the late term results of minimally invasive plate fixation for distal radius fractures (DRF) and compare it to the treatment outcomes for patients with similar injuries where internal fixation was performed through conventional volar surgical approach. Material and Methods. 96 patients with DRF fractures were included into the study who underwent volar plate fixation by with angular stability. The main group included 42 patients (29 women and 13 men) with DMR where minimally invasive volar approach was used. Mean age of patients was 38 years (from 21 to 57 years). Control group consisted of 54 patients (33 women and 21 men) with mean age of 43 years (from 26 to 64 years) who underwent fracture stabilization via conventional volar approach. Minimal follow up after surgery and discharge was 3 months. In the late period roentgenological, functional and cosmetic outcomes were evaluated as well as patients’ satisfaction by QuickDASH-9 survey. Results. 95 patients (98.9%) demonstrated fracture consolidation in terms up to 6 weeks irrespective of surgical technique which was confirmed by X-rays during control examination. In one female patient (1.1%) consolidation following minimally invasive plating was not achieved even in one year after surgery which was considered as distal radius pseudarthrosis but featuring excellent functional outcome. Surgery time for minimally invasive fixation was 47 (41;53) minutes and for conventional surgical approach – 43 (37;46) minutes (р = 0.731). Mean time of image intensifier use during internal fixation averaged 54 (47;63) seconds during minimally invasive technique and 33 (29;37) seconds for conventional open technique (р = 0.046). Statistically significant larger flexion and extension ranges, pronation and supination angles as well as higher grip force were observed in the group of minimally invasive internal fixation in 1, 2 and 3 months after the surgery (р<0.001). Statistically lower scores for QuickDASH-9 survey were reported for the main group in 2 and 3 months postoperatively (р<0.001). Cosmetic results were better in patients after minimally invasive approach. Conclusion. Minimally invasive plating fixation of DRF is the efficient and relatively safe surgical option for such injuries. The key arguments for such approach: preservation of bone vascularization which minimally slows down fracture healing, reduced risk of infectious complications, fast functional wrist recovery already in early postoperative period as well as satisfaction of patients with cosmetic effects.

作者简介

B. Maximov

Moscow City Hospital No. 29 named after N.E. Bauman

编辑信件的主要联系方式.
Email: dr.borismaximov@gmail.com

Boris I. Maximov — Cand. Sci. (Med.), Head of the Traumatology and Orthopedics Department

Moscow

俄罗斯联邦

参考

  1. Court-Brown C.M., Caesar B. Epidemiology of adult fractures: A review. Injury. 2006;37(8):691-697. doi: 10.1016/j.injury.2006.04.130.
  2. Chung K.C., Spilson S.V. The frequency and epidemiology of hand and forearm fractures in the United States. J Hand Surg Am. 2001;26(5):908-915. doi: 10.1053/jhsu.2001.26322.
  3. Skouras E., Hosseini Y., Berger V., Wegmann K., Koslowsky T.C. Operative treatment and outcome of unstable distal radial fractures using a palmar T-miniplate at a nonspecialized institution. Strateg Trauma Limb Reconstr. 2013;8(3):155-160. doi: 10.1007/s11751-013-0170-y.
  4. Хоминец В.В., Ткаченко М.В., Сырцов В.В., Иванов В.С. Сравнительный анализ способов лечения больных с переломами дистального метаэпифиза лучевой кости. Травматология и ортопедия России. 2015;(2)5-15. doi: 10.21823/2311-2905-2015-0-2-5-15.
  5. Imatani J., Noda T., Morito Y., Sato T., Hashizume H., Inoue H. Minimally invasive plate osteosynthesis for comminuted fractures of the metaphysis of the radius. J Hand Surg Br. 2005;30(2):220-225. doi: 10.1016/j.jhsb.2004.12.009.
  6. Takada N., Otsuka T., Yamada K., Suzuki H., Hasuo T., Kondo A., Fukuta M. Minimally invasive plate osteosynthesis for distal radius fractures with a palmar locking plate. Eur J Trauma Emerg Surg. 2012;38(6): 627-632. doi: 10.1007/s00068-012-0204z.
  7. Geissler W.B., Fernandes D. Percutaneous and limited open reduction of intra-articular distal radial fractures. Hand Surg. 2000;5(2):85-92. doi: 10.1142/s0218810400000193.
  8. Zenke Y., Sakai A., Oshige T., Moritani S., Fuse Y., Maehara T., Nakamura T. Clinical results of volar locking plate for distal radius fractures: conventional versus minimally invasive plate osteosynthesis. J Orthop Trauma. 2011;25(7):425-431. doi: 10.1097/bot.0b013e3182008c83.
  9. Chen C.Y., Lin K.C., Yang S.W., Renn J.H., Tarng Y.W. Clinical results of using minimally invasive long plate osteosynthesis versus conventional approach for extensive comminuted metadiaphyseal fractures of the radius. Arch Orthop Trauma Surg. 2015;135(3):361-367. doi: 10.1007/s00402-015-2162-5.
  10. Lebailly F., Zemirline A., Facca S., Gouzou S., Liverneaux P. Distal radius fixation through a miniinvasive approach of 15 mm. Part 1: a series of 144 cases. Eur J Orthop Surg Traumatol. 2014;24(6):877-890. doi: 10.1007/s00590-013-1363-2.
  11. Максимов Б.И., Артемьев А.А. Малоинвазивный накостный остеосинтез дистального метаэпифиза лучевой кости: показания к применению и особенности методики. Вопросы реконструктивной и пластической хирургии. 2017;2(61):61-66. doi: 10.17223/1814147/60/07.
  12. Wei X.M., Sun Z.Z., Rui Y.J., Song X.J. Minimally invasive plate osteosynthesis for distal radius fractures. Indian J Orthop. 2014;48(1):20-24. doi: 10.4103/0019-5413.125483.
  13. Armangil M., Bezirgan U., Basarır K., Bilen G., Demirtas M., Bilgin S.S. The pronator quadratus muscle after plating of distal radius fractures: is the muscle still working? Eur J Orthop Surg Traumatol. 2014;24(3):335-339. doi: 10.1007/s00590-013-1193-2.
  14. Fernandez D.L., Jupiter J.B. Fractures of the distal radius. New York: Springer-Verlag; 1996. 407 р. doi: 10.1007/978-1-4684-0478-4.
  15. Orbay J.L., Fernandez D.L. Volar fixation of dorsally displaced fractures of the distal radius: a preliminary report. J Hand Surg. 2002;27(2):205-215. doi: 10.1053/jhsu.2002.32081.
  16. Kapoor H., Agarwal A., Dhaon B. Displaced intraarticular fractures of distal radius: A comparative evaluation of results following closed reduction, external fixation and open reduction with internal fixation. Injury. 2000;31(2):75-79. doi: 10.1016/s0020-1383(99)00207-7.
  17. Gordon K.D., Dunning C.E., Johnson J.A., King G.J. Influence of the pronator quadratus and supinator muscle load on DRUJ stability. J Hand Surg Am. 2003;28(6):943-950. doi: 10.1016/s0363-5023(03)00487-8.
  18. Максимов Б.И., Пандунц А.А., Ведерников Н.Н. Возможности сохранения квадратного пронатора предплечья при хирургическом лечении переломов дистального отдела лучевой кости. Вестник национального медико-хирургического центра им. Н.И. Пирогова. 2018;13(4):49-52. doi: 10.25881/BPNMSC.2018.22.37.008.
  19. Ahsan Z.S., Yao J. The importance of pronator quadratus repair in the treatment of distal radius fractures with volar plating. Hand (NY). 2012;7(3):276-280. doi: 10.1007/s11552-012-9420-6.
  20. Lau T., Leung F., Chan C., Chow S. Minimally invasive plate osteosynthesis in the treatment of proximal humeral fracture. Int Orthop. 2007;31(5):657-664. doi: 10.1007/s00264-006-0242-4.
  21. Ronga M., Shanmugam C., Longo U.G., Oliva F., Maffulli N. Minimally invasive osteosynthesis of distal tibial fractures using locking plates. Orthop Clin North Am. 2009;40(4):499-504. doi: 10.1016/j.ocl.2009.05.007.
  22. Cannon T.A., Carlston C.V., Stevanovic M.V., Ghiassi A.D. Pronator-sparing technique for volar plating of distal radius fractures. J Hand Surg Am. 2014;39(12):25062511. doi: 10.1016/j.jhsa.2014.09.011.
  23. Sun Z.Z., Rui Y.J., Song X.J., Wei X.M, Minimally invasive plate osteosynthesis for distal radius fractures. Indian J Orthop. 2014;48(1):20-24. doi: 10.4103/0019-5413.125483.
  24. McKay S.D., MacDermid J.C., Roth J.H., Richards R.S. Assessment of complications of distal radius fractures and development of a complication checklist. J Hand Surg. 2001;26(5):916-922. doi: 10.1053/jhsu.2001.26662.

补充文件

附件文件
动作
1. JATS XML

版权所有 © Traumatology and Orthopedics of Russia, 2023

Согласие на обработку персональных данных с помощью сервиса «Яндекс.Метрика»

1. Я (далее – «Пользователь» или «Субъект персональных данных»), осуществляя использование сайта https://journals.rcsi.science/ (далее – «Сайт»), подтверждая свою полную дееспособность даю согласие на обработку персональных данных с использованием средств автоматизации Оператору - федеральному государственному бюджетному учреждению «Российский центр научной информации» (РЦНИ), далее – «Оператор», расположенному по адресу: 119991, г. Москва, Ленинский просп., д.32А, со следующими условиями.

2. Категории обрабатываемых данных: файлы «cookies» (куки-файлы). Файлы «cookie» – это небольшой текстовый файл, который веб-сервер может хранить в браузере Пользователя. Данные файлы веб-сервер загружает на устройство Пользователя при посещении им Сайта. При каждом следующем посещении Пользователем Сайта «cookie» файлы отправляются на Сайт Оператора. Данные файлы позволяют Сайту распознавать устройство Пользователя. Содержимое такого файла может как относиться, так и не относиться к персональным данным, в зависимости от того, содержит ли такой файл персональные данные или содержит обезличенные технические данные.

3. Цель обработки персональных данных: анализ пользовательской активности с помощью сервиса «Яндекс.Метрика».

4. Категории субъектов персональных данных: все Пользователи Сайта, которые дали согласие на обработку файлов «cookie».

5. Способы обработки: сбор, запись, систематизация, накопление, хранение, уточнение (обновление, изменение), извлечение, использование, передача (доступ, предоставление), блокирование, удаление, уничтожение персональных данных.

6. Срок обработки и хранения: до получения от Субъекта персональных данных требования о прекращении обработки/отзыва согласия.

7. Способ отзыва: заявление об отзыве в письменном виде путём его направления на адрес электронной почты Оператора: info@rcsi.science или путем письменного обращения по юридическому адресу: 119991, г. Москва, Ленинский просп., д.32А

8. Субъект персональных данных вправе запретить своему оборудованию прием этих данных или ограничить прием этих данных. При отказе от получения таких данных или при ограничении приема данных некоторые функции Сайта могут работать некорректно. Субъект персональных данных обязуется сам настроить свое оборудование таким способом, чтобы оно обеспечивало адекватный его желаниям режим работы и уровень защиты данных файлов «cookie», Оператор не предоставляет технологических и правовых консультаций на темы подобного характера.

9. Порядок уничтожения персональных данных при достижении цели их обработки или при наступлении иных законных оснований определяется Оператором в соответствии с законодательством Российской Федерации.

10. Я согласен/согласна квалифицировать в качестве своей простой электронной подписи под настоящим Согласием и под Политикой обработки персональных данных выполнение мною следующего действия на сайте: https://journals.rcsi.science/ нажатие мною на интерфейсе с текстом: «Сайт использует сервис «Яндекс.Метрика» (который использует файлы «cookie») на элемент с текстом «Принять и продолжить».